A connecting accessory that can be used in hospitals and surgical centres with electrosurgical generators and is reliable. Designed for reliable current transfer, safety, and long term use with repeated sterilization cycles in a Pakistani OT setting using an electrosurgical unit accessory.Â
Specifications:
Material: Medical grade silicone insulated with a copper conductor core for safety.
Compatibility: Standard and generator specific connectors are both compatible.
Switching accessories for bipolar electrosurgical generators with hand operation. It allows the surgeon to control coagulation or cutting from the hand piece without the need for a foot pedal, allowing for a more focused operation with a reliable bipolar hand controller solution.Â
Specifications:
Type: Bipolar hand activated control switch
Compatibility: Standard bipolar electrosurgical generator interface
Single use electrodes for the recording of the ECG, for stress tests, and for continuous cardiac monitoring, which are attached by adhesive. Stable skin contact and low noise signal transmission for hospital, clinic or home care with reliable ECG electrodes.Â
Specifications
Sensing element: Silver/silver chloride (Ag/AgCl)Type: Disposable, single useAdhesive: Medical grade hydrogelBacking material: Hypoallergenic foam or clothPackaging: Individually sealed, maintain gel's moisture until useApplication: 12 lead ECG, stress testing, Holter monitoringCompatibility: Standard ECG machines and monitoring leadsStorage condition: Cool, dry place away from direct heat and sunlightShelf life: 1 to 3 years from manufacture (refer to batch label)Skin suitability: Suitable for adult and pediatric use (confirm sizing for pediatric patients)
Return electrode for monopolar electrosurgical use, designed for single use as an electrosurgical pad. It can cover the existing path safely between the patient and the electrosurgical generator and thus reduce the risk of burns during surgery with an electrosurgical pad.Â
Specifications:
Type: Split pad, REM (Return Electrode Monitoring) compatible
Material: Latex free, hypoallergenic adhesive gel
Backing: Flexible, conformable non woven backing
Adhesive: Conductive hydrogel with strong, skin safe tack
Sterility: Individually sealed, single patient use
Shelf life: Typically 2–3 years from manufacture (check batch label)
Compatibility: Works with standard monopolar electrosurgical generators
Packaging: Available in boxes for bulk hospital/clinic ordering
A monopolar cable 8mm male 4.8mm female connector can be used multiple times to join an electrosurgical pencil or handpiece to an electrosurgical generator to pass current between them during surgical operations to cut and coagulate tissue.Â
Specifications:
Connector type:8mm male (generator end) to 4.8mm Female (handpiece end)Â
Compatibility:Connects to standard 8mm output sockets on generators and 4.8mm banana style plug handpieces/pencilsÂ
Insulation:Silicone body, flexible and tear resistantÂ
Sterilization: Autoclavable, suitable for repeated steam sterilization cycles
Conductor:Low resistance to deliver consistent energyÂ
Build:Reinforced strain relief in both connector joints to minimise wear caused by repeated use
Use case: General surgery, minor procedures, OT and clinic settings
Reusability:Not designed for single use but designed for multiple use and sterilisation
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
Type: Single use, disposable return electrode / grounding pad
Material: Latex free, hypoallergenic conductive material
Adhesive: Skin safe gel adhesive for secure, stable contact
A manual switching device that is designed to start, stop, or control machinery and electrical circuits using push button control. Designed for factory panels, generator changeover, and equipment where a fast and reliable manual operation is required. Designed to address Pakistan's range of power supplies and the rigours of workshop applications with push button control.Â
Specifications:
Type: Momentary and maintained contact options available
Actuator Colors: Red, green, yellow, black (customizable per function)
Panel Cutout Size: 22 mm and 16 mm standard fittings
Protection Rating: IP65 available for dust and moisture resistance
Wiring: Screw terminal connection for easy installation
Contact Configuration: 1 NO / 1 NC (normally open / normally closed), higher configurations available on request
Voltage Rating: Suitable for standard AC control circuits with fluctuation tolerance
Operating Temperature: Rated for high heat industrial environments
Mounting: Panel mount, standard control box compatible
Body Material: Impact resistant plastic or metal housing (depending on variant)
The bipolar forceps are powered by a reusable, autoclavable bipolar cable, which runs directly from the bipolar forceps to a European standard electrosurgical generator. Medical grade silicone insulation allows it to be washed and sterilized repeatedly, and it is a long lasting, cost effective solution over disposable cables. A reusable silicone bipolar cable European standard connector provides a dependable connection for repeated surgical use.Â
Specifications:
Connector type: European standard bipolar connector
Material:Medical grade silicone materialÂ
Sterilization:Safe for repeated autoclave cycles (may be steam autoclave safe)Â
Usage:Re useable (multi cycle, not single use)Â
Compatibility:Compatible with European style bipolar generators and bipolar forcepsÂ
Cable design:Flexible, kink resistant body for easy handling in the surgical field
Connector housing: Sealed against steam penetration to protect internal contacts from corrosion