Designed for hospitals and clinics that require a reliable, easy to sterilize cable for everyday theatre use, this reusable bipolar cable BOWA is compatible with bipolar forceps and instruments with BOWA electrosurgical generators.
Specifications:
Compatibility:BOWA electrosurgical generator systems (bipolar output)Â
Connector type:Special bipolar pin connector, perfectly matched to BOWA socketÂ
Core material:Low resistance copper conductorÂ
Insulation:Reinforced silicone sheathingÂ
Sterilization:Autoclavable, suitable for repeated steam sterilizations
Reusability:Multi use and reprocessable, not single use
Cable design: Flexible, kink resistant, consistent length for reliable field handling
Application:Bipolar electrosurgery (no grounding pad/neutral electrode is needed)Â
Intended use setting:Surgical theatres, clinical surgery, biomedical in hospitals
A stable and safe return cable for the patient return plates to the electrosurgical generators for monopolar surgical procedures. The bipolar earth plate cable 6mm provides a stable connection between the patient return plate and the electrosurgical generator.Â
Specifications:
Conductor size:6mm earth conductor coreÂ
Insulation:High grade silicone with heat and autoclave resistanceÂ
Conductor material:Stable current return with low resistance copperÂ
Connector type:Commonly used electrosurgical generator standard fittingsÂ
Jacket:Kink resistant outer sheath that is flexible
Sterilization:Autoclavable and can be used repeatedly in hospitals for hospital sterilisation cyclesÂ
Reusability: Reusable across multiple procedures with proper maintenance
Application:Monopolar electrosurgery units for hospitals, surgical clinics, OT
Switching accessories for bipolar electrosurgical generators with hand operation. It allows the surgeon to control coagulation or cutting from the hand piece without the need for a foot pedal, allowing for a more focused operation with a reliable bipolar hand controller solution.Â
Specifications:
Type: Bipolar hand activated control switch
Compatibility: Standard bipolar electrosurgical generator interface
A one time surgical instrument for cutting and coagulating tissue during surgery, the disposable electrosurgical pencil eliminates the risk of cross contamination and provides known electrosurgical performance in each surgery.Â
Single use electrodes for the recording of the ECG, for stress tests, and for continuous cardiac monitoring, which are attached by adhesive. Stable skin contact and low noise signal transmission for hospital, clinic or home care with reliable ECG electrodes.Â
Specifications
Sensing element: Silver/silver chloride (Ag/AgCl)Type: Disposable, single useAdhesive: Medical grade hydrogelBacking material: Hypoallergenic foam or clothPackaging: Individually sealed, maintain gel's moisture until useApplication: 12 lead ECG, stress testing, Holter monitoringCompatibility: Standard ECG machines and monitoring leadsStorage condition: Cool, dry place away from direct heat and sunlightShelf life: 1 to 3 years from manufacture (refer to batch label)Skin suitability: Suitable for adult and pediatric use (confirm sizing for pediatric patients)
Return electrode for monopolar electrosurgical use, designed for single use as an electrosurgical pad. It can cover the existing path safely between the patient and the electrosurgical generator and thus reduce the risk of burns during surgery with an electrosurgical pad.Â
Specifications:
Type: Split pad, REM (Return Electrode Monitoring) compatible
Material: Latex free, hypoallergenic adhesive gel
Backing: Flexible, conformable non woven backing
Adhesive: Conductive hydrogel with strong, skin safe tack
Sterility: Individually sealed, single patient use
Shelf life: Typically 2–3 years from manufacture (check batch label)
Compatibility: Works with standard monopolar electrosurgical generators
Packaging: Available in boxes for bulk hospital/clinic ordering
A long lasting instrument for electrosurgery, linking the generator to a monopolar handpiece for the administration of a steady current for cutting and coagulation during surgery. The monopolar cable 4mm female to male connector provides a dependable connection between compatible electrosurgical equipment.Â
Specifications:
Connector type:4mm female to maleÂ
Conductor: Low resistance copper core
Insulation:Silicone, autoclavableÂ
Standard length:3 metres (also available in 2 m and 4 m)Â
Compatibility: Standard monopolar electrosurgical generators
Sterilization: Autoclave safe, reusable
Build: Reinforced strain relief at both ends of connectors
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
Type: Single use, disposable return electrode / grounding pad
Material: Latex free, hypoallergenic conductive material
Adhesive: Skin safe gel adhesive for secure, stable contact
Reviews
There are no reviews yet.