The bipolar cable for Valleylab cable is designed for reuse and daily use with Valleylab bipolar forceps in the operating room, and it is suitable for repeated sterilization.Â
Specifications:
Plug type:European bipolar connector with 29 mm spacingÂ
A stable and safe return cable for the patient return plates to the electrosurgical generators for monopolar surgical procedures. The bipolar earth plate cable 6mm provides a stable connection between the patient return plate and the electrosurgical generator.Â
Specifications:
Conductor size:6mm earth conductor coreÂ
Insulation:High grade silicone with heat and autoclave resistanceÂ
Conductor material:Stable current return with low resistance copperÂ
Connector type:Commonly used electrosurgical generator standard fittingsÂ
Jacket:Kink resistant outer sheath that is flexible
Sterilization:Autoclavable and can be used repeatedly in hospitals for hospital sterilisation cyclesÂ
Reusability: Reusable across multiple procedures with proper maintenance
Application:Monopolar electrosurgery units for hospitals, surgical clinics, OT
A connecting accessory that can be used in hospitals and surgical centres with electrosurgical generators and is reliable. Designed for reliable current transfer, safety, and long term use with repeated sterilization cycles in a Pakistani OT setting using an electrosurgical unit accessory.Â
Specifications:
Material: Medical grade silicone insulated with a copper conductor core for safety.
Compatibility: Standard and generator specific connectors are both compatible.
A cable with a bipolar forceps cable attachment is to be used with the electrosurgical generator for the exactness of tissue coagulation during surgery. Constructed with autoclave safe insulation and a rugged connector for daily use in the OT.Â
Specifications:
Type: Bipolar electrosurgical cable
Connector: Dual pin bipolar connector (standard fit for major generator brands)
Cable Length: 3 meters (approx.)
Insulation Material: Medical grade silicone
Sterilization: Autoclavable up to 134°C
Reusability:Can have multiple sterilization cycles because it is reusableÂ
Compatibility:Standard bipolar forceps and electrosurgical generators
Voltage Rating:Electrosurgical generator output stable with varying input powerÂ
One time patient return electrode in monopolar electrosurgery to safely complete the electrical circuit, directing current away from the patient's body and preventing burns during surgical procedures. The disposable monopolar earth plate provides a safe patient return path during the procedure.Â
Specifications:
Type:Disposable, non sterile/sterile (based on the model)Â
Design: Split pad or solid pad configuration
Adhesive:Consistent skin contact provided by the conductive hydrogel layer
A dual pedal foot control that is used in conjunction with electrosurgical units to turn them on and off during surgery without using your hands. The ESU foot switch is intended for repeated use in hospital and clinic operation theatres.Â
Specifications:
Type: Dual pedal (Cut / Coagulation)Compatibility: Standard ESU generator input, compatible with common electrosurgical unitsHousing: Sealed, spill and fluid resistant constructionBase: Non slip rubber base for stable floor gripCable: Reinforced, heavy duty cable resistant to crackingConnector: Standard pinout for direct plug in, no modification neededActivation: Firm tactile press point to prevent accidental triggeringUsage environment: Designed for daily, high frequency OT use
A long lasting instrument for electrosurgery, linking the generator to a monopolar handpiece for the administration of a steady current for cutting and coagulation during surgery. The monopolar cable 4mm female to male connector provides a dependable connection between compatible electrosurgical equipment.Â
Specifications:
Connector type:4mm female to maleÂ
Conductor: Low resistance copper core
Insulation:Silicone, autoclavableÂ
Standard length:3 metres (also available in 2 m and 4 m)Â
Compatibility: Standard monopolar electrosurgical generators
Sterilization: Autoclave safe, reusable
Build: Reinforced strain relief at both ends of connectors
The bipolar forceps are powered by a reusable, autoclavable bipolar cable, which runs directly from the bipolar forceps to a European standard electrosurgical generator. Medical grade silicone insulation allows it to be washed and sterilized repeatedly, and it is a long lasting, cost effective solution over disposable cables. A reusable silicone bipolar cable European standard connector provides a dependable connection for repeated surgical use.Â
Specifications:
Connector type: European standard bipolar connector
Material:Medical grade silicone materialÂ
Sterilization:Safe for repeated autoclave cycles (may be steam autoclave safe)Â
Usage:Re useable (multi cycle, not single use)Â
Compatibility:Compatible with European style bipolar generators and bipolar forcepsÂ
Cable design:Flexible, kink resistant body for easy handling in the surgical field
Connector housing: Sealed against steam penetration to protect internal contacts from corrosion
Reviews
There are no reviews yet.