A connecting accessory that can be used in hospitals and surgical centres with electrosurgical generators and is reliable. Designed for reliable current transfer, safety, and long term use with repeated sterilization cycles in a Pakistani OT setting using an electrosurgical unit accessory.Â
Specifications:
Material: Medical grade silicone insulated with a copper conductor core for safety.
Compatibility: Standard and generator specific connectors are both compatible.
One time grounding pad for safe, reliable return of current for monopolar electrosurgical procedures. Designed to be used every time with every patient in hospitals and clinics, the disposable earth plate bipolar provides a practical option without compromising performance.Â
Specifications:
Type: Disposable, single use return electrode pad
Compatibility: Uses typical monopolar electrosurgical generators, including REM (return electrode monitoring) generatorsÂ
Adhesive: Safe for skin and leaves no residue on removal
Conductive layer: Even gel distribution for consistent impedance and reduced burn risk
Packaging: Sterile and individually sealed until opened
Shelf life: Will store for long periods of time, ideal for bulk stockers such as hospitals and distributors.Â
Application area: Suitable for adult and pediatric use on clean, well vascularized skin
Power stability: Smooth operation even when the power is irregular from alternative power supplies
One time patient return electrode in monopolar electrosurgery to safely complete the electrical circuit, directing current away from the patient's body and preventing burns during surgical procedures. The disposable monopolar earth plate provides a safe patient return path during the procedure.Â
Specifications:
Type:Disposable, non sterile/sterile (based on the model)Â
Design: Split pad or solid pad configuration
Adhesive:Consistent skin contact provided by the conductive hydrogel layer
Single use electrodes for the recording of the ECG, for stress tests, and for continuous cardiac monitoring, which are attached by adhesive. Stable skin contact and low noise signal transmission for hospital, clinic or home care with reliable ECG electrodes.Â
Specifications
Sensing element: Silver/silver chloride (Ag/AgCl)Type: Disposable, single useAdhesive: Medical grade hydrogelBacking material: Hypoallergenic foam or clothPackaging: Individually sealed, maintain gel's moisture until useApplication: 12 lead ECG, stress testing, Holter monitoringCompatibility: Standard ECG machines and monitoring leadsStorage condition: Cool, dry place away from direct heat and sunlightShelf life: 1 to 3 years from manufacture (refer to batch label)Skin suitability: Suitable for adult and pediatric use (confirm sizing for pediatric patients)
A long, reusable Martin bipolar cable to deliver bipolar current to bipolar forceps for accurate tissue coagulation during surgery. Designed for repeated autoclave sterilisation and everyday OT use.Â
Specifications:
Connector type:Martin style bipolar plugÂ
Cable length: 2.5 m / 3 m (standard options)
Insulation: Silicone jacket
Conductor: Copper core, low resistance braid
Sterilization:Autoclavable, standard hospital cyclesÂ
Reusability: Multi use, reusable cable
Compatible with:Generators with Martin standard bipolar connectorsÂ
A monopolar cable 8mm male 4.8mm female connector can be used multiple times to join an electrosurgical pencil or handpiece to an electrosurgical generator to pass current between them during surgical operations to cut and coagulate tissue.Â
Specifications:
Connector type:8mm male (generator end) to 4.8mm Female (handpiece end)Â
Compatibility:Connects to standard 8mm output sockets on generators and 4.8mm banana style plug handpieces/pencilsÂ
Insulation:Silicone body, flexible and tear resistantÂ
Sterilization: Autoclavable, suitable for repeated steam sterilization cycles
Conductor:Low resistance to deliver consistent energyÂ
Build:Reinforced strain relief in both connector joints to minimise wear caused by repeated use
Use case: General surgery, minor procedures, OT and clinic settings
Reusability:Not designed for single use but designed for multiple use and sterilisation
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
Type: Single use, disposable return electrode / grounding pad
Material: Latex free, hypoallergenic conductive material
Adhesive: Skin safe gel adhesive for secure, stable contact
A safe, stable, long lasting, autoclavable grounding cable used to provide connections between the patient return plate and the electrosurgical unit (ESU) during surgery. Made for reuse at the hospital, the reusable silicone earth patient plate cable is a more cost effective and longer lasting replacement for disposable cables.Â
Specifications:
Material:Medical grade siliconeÂ
Type:Reusable (not single use)Â
Sterilization:Autoclave compatibleÂ
Connector:Standard ESU compatible connector endsÂ
Length: 3–5 meters (longer lengths on request)Â
Conductivity: Stable continuity under continuous load
Durability:Reinforced strain relief at connector points
Operating Conditions: Heat and humidity resistant
Use Case:ESU grounding for electrocautery proceduresÂ
Compatibility:Common and compatible with the most popular brands used in hospitals and clinics in Pakistan