A stable and safe return cable for the patient return plates to the electrosurgical generators for monopolar surgical procedures. The bipolar earth plate cable 6mm provides a stable connection between the patient return plate and the electrosurgical generator.Â
Specifications:
Conductor size:6mm earth conductor coreÂ
Insulation:High grade silicone with heat and autoclave resistanceÂ
Conductor material:Stable current return with low resistance copperÂ
Connector type:Commonly used electrosurgical generator standard fittingsÂ
Jacket:Kink resistant outer sheath that is flexible
Sterilization:Autoclavable and can be used repeatedly in hospitals for hospital sterilisation cyclesÂ
Reusability: Reusable across multiple procedures with proper maintenance
Application:Monopolar electrosurgery units for hospitals, surgical clinics, OT
A single use patient return electrode (earth plate) designed to function with ValleyLab compatible electrosurgical units. It has a skin friendly conductive adhesive layer that distributes current evenly over the contact area, leaving the patient's skin protected and keeping the electrosurgical circuit safe. It is disposable and doesn't pose the risk of cross contamination from reusable plates and doesn't require any cleaning or sterilisation between patients. A disposable earth plate ValleyLab connector provides the required connection for compatible electrosurgical units.Â
A one time surgical instrument for cutting and coagulating tissue during surgery, the disposable electrosurgical pencil eliminates the risk of cross contamination and provides known electrosurgical performance in each surgery.Â
Single use electrodes for the recording of the ECG, for stress tests, and for continuous cardiac monitoring, which are attached by adhesive. Stable skin contact and low noise signal transmission for hospital, clinic or home care with reliable ECG electrodes.Â
Specifications
Sensing element: Silver/silver chloride (Ag/AgCl)Type: Disposable, single useAdhesive: Medical grade hydrogelBacking material: Hypoallergenic foam or clothPackaging: Individually sealed, maintain gel's moisture until useApplication: 12 lead ECG, stress testing, Holter monitoringCompatibility: Standard ECG machines and monitoring leadsStorage condition: Cool, dry place away from direct heat and sunlightShelf life: 1 to 3 years from manufacture (refer to batch label)Skin suitability: Suitable for adult and pediatric use (confirm sizing for pediatric patients)
Return electrode for monopolar electrosurgical use, designed for single use as an electrosurgical pad. It can cover the existing path safely between the patient and the electrosurgical generator and thus reduce the risk of burns during surgery with an electrosurgical pad.Â
Specifications:
Type: Split pad, REM (Return Electrode Monitoring) compatible
Material: Latex free, hypoallergenic adhesive gel
Backing: Flexible, conformable non woven backing
Adhesive: Conductive hydrogel with strong, skin safe tack
Sterility: Individually sealed, single patient use
Shelf life: Typically 2–3 years from manufacture (check batch label)
Compatibility: Works with standard monopolar electrosurgical generators
Packaging: Available in boxes for bulk hospital/clinic ordering
A long lasting instrument for electrosurgery, linking the generator to a monopolar handpiece for the administration of a steady current for cutting and coagulation during surgery. The monopolar cable 4mm female to male connector provides a dependable connection between compatible electrosurgical equipment.Â
Specifications:
Connector type:4mm female to maleÂ
Conductor: Low resistance copper core
Insulation:Silicone, autoclavableÂ
Standard length:3 metres (also available in 2 m and 4 m)Â
Compatibility: Standard monopolar electrosurgical generators
Sterilization: Autoclave safe, reusable
Build: Reinforced strain relief at both ends of connectors
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
Type: Single use, disposable return electrode / grounding pad
Material: Latex free, hypoallergenic conductive material
Adhesive: Skin safe gel adhesive for secure, stable contact
The bipolar forceps are powered by a reusable, autoclavable bipolar cable, which runs directly from the bipolar forceps to a European standard electrosurgical generator. Medical grade silicone insulation allows it to be washed and sterilized repeatedly, and it is a long lasting, cost effective solution over disposable cables. A reusable silicone bipolar cable European standard connector provides a dependable connection for repeated surgical use.Â
Specifications:
Connector type: European standard bipolar connector
Material:Medical grade silicone materialÂ
Sterilization:Safe for repeated autoclave cycles (may be steam autoclave safe)Â
Usage:Re useable (multi cycle, not single use)Â
Compatibility:Compatible with European style bipolar generators and bipolar forcepsÂ
Cable design:Flexible, kink resistant body for easy handling in the surgical field
Connector housing: Sealed against steam penetration to protect internal contacts from corrosion
Reviews
There are no reviews yet.