A stable and safe return cable for the patient return plates to the electrosurgical generators for monopolar surgical procedures. The bipolar earth plate cable 6mm provides a stable connection between the patient return plate and the electrosurgical generator.Â
Specifications:
Conductor size:6mm earth conductor coreÂ
Insulation:High grade silicone with heat and autoclave resistanceÂ
Conductor material:Stable current return with low resistance copperÂ
Connector type:Commonly used electrosurgical generator standard fittingsÂ
Jacket:Kink resistant outer sheath that is flexible
Sterilization:Autoclavable and can be used repeatedly in hospitals for hospital sterilisation cyclesÂ
Reusability: Reusable across multiple procedures with proper maintenance
Application:Monopolar electrosurgery units for hospitals, surgical clinics, OT
A single use patient return electrode (earth plate) designed to function with ValleyLab compatible electrosurgical units. It has a skin friendly conductive adhesive layer that distributes current evenly over the contact area, leaving the patient's skin protected and keeping the electrosurgical circuit safe. It is disposable and doesn't pose the risk of cross contamination from reusable plates and doesn't require any cleaning or sterilisation between patients. A disposable earth plate ValleyLab connector provides the required connection for compatible electrosurgical units.Â
A one time surgical instrument for cutting and coagulating tissue during surgery, the disposable electrosurgical pencil eliminates the risk of cross contamination and provides known electrosurgical performance in each surgery.Â
Single use electrodes for the recording of the ECG, for stress tests, and for continuous cardiac monitoring, which are attached by adhesive. Stable skin contact and low noise signal transmission for hospital, clinic or home care with reliable ECG electrodes.Â
Specifications
Sensing element: Silver/silver chloride (Ag/AgCl)Type: Disposable, single useAdhesive: Medical grade hydrogelBacking material: Hypoallergenic foam or clothPackaging: Individually sealed, maintain gel's moisture until useApplication: 12 lead ECG, stress testing, Holter monitoringCompatibility: Standard ECG machines and monitoring leadsStorage condition: Cool, dry place away from direct heat and sunlightShelf life: 1 to 3 years from manufacture (refer to batch label)Skin suitability: Suitable for adult and pediatric use (confirm sizing for pediatric patients)
Return electrode for monopolar electrosurgical use, designed for single use as an electrosurgical pad. It can cover the existing path safely between the patient and the electrosurgical generator and thus reduce the risk of burns during surgery with an electrosurgical pad.Â
Specifications:
Type: Split pad, REM (Return Electrode Monitoring) compatible
Material: Latex free, hypoallergenic adhesive gel
Backing: Flexible, conformable non woven backing
Adhesive: Conductive hydrogel with strong, skin safe tack
Sterility: Individually sealed, single patient use
Shelf life: Typically 2–3 years from manufacture (check batch label)
Compatibility: Works with standard monopolar electrosurgical generators
Packaging: Available in boxes for bulk hospital/clinic ordering
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
Type: Single use, disposable return electrode / grounding pad
Material: Latex free, hypoallergenic conductive material
Adhesive: Skin safe gel adhesive for secure, stable contact
A manual switching device that is designed to start, stop, or control machinery and electrical circuits using push button control. Designed for factory panels, generator changeover, and equipment where a fast and reliable manual operation is required. Designed to address Pakistan's range of power supplies and the rigours of workshop applications with push button control.Â
Specifications:
Type: Momentary and maintained contact options available
Actuator Colors: Red, green, yellow, black (customizable per function)
Panel Cutout Size: 22 mm and 16 mm standard fittings
Protection Rating: IP65 available for dust and moisture resistance
Wiring: Screw terminal connection for easy installation
Contact Configuration: 1 NO / 1 NC (normally open / normally closed), higher configurations available on request
Voltage Rating: Suitable for standard AC control circuits with fluctuation tolerance
Operating Temperature: Rated for high heat industrial environments
Mounting: Panel mount, standard control box compatible
Body Material: Impact resistant plastic or metal housing (depending on variant)
A durable, autoclavable bipolar cable that links bipolar forceps to the electrosurgical generator, with a reusable silicone bipolar cable and an American design made for repeated use in the hectic surgical environment.Â
Specifications:
Type:Reusable Bipolar (RBC) Cable from American Standard
Connector Style:American pin type (forceps end and generator end)Â
Reviews
There are no reviews yet.