Electrosurgical generators with a pedal operated control device activate the bipolar cutting and coagulation modes without the operator having to leave the operating field, making the bipolar foot switch an essential control accessory during surgical procedures.Â
Specifications:
Type:Dual pedal bipolar activation (separate cut and coagulation controls)
Housing:Sealed, spill and fluid resistant casing for OT environmentÂ
Base:Non slip rubberized underside for stability on smooth floorsÂ
Switch rating:High cycle microswitches used every day during clinical operationsÂ
Connector: Standard compatibility with common electrosurgical generator ports
Design: Low level, compact footprint to reduce OT floor clutter
Build: Designed to operate for extended periods and multiple operations as needed
A cable with a bipolar forceps cable attachment is to be used with the electrosurgical generator for the exactness of tissue coagulation during surgery. Constructed with autoclave safe insulation and a rugged connector for daily use in the OT.Â
Specifications:
Type: Bipolar electrosurgical cable
Connector: Dual pin bipolar connector (standard fit for major generator brands)
Cable Length: 3 meters (approx.)
Insulation Material: Medical grade silicone
Sterilization: Autoclavable up to 134°C
Reusability:Can have multiple sterilization cycles because it is reusableÂ
Compatibility:Standard bipolar forceps and electrosurgical generators
Voltage Rating:Electrosurgical generator output stable with varying input powerÂ
A one time surgical instrument for cutting and coagulating tissue during surgery, the disposable electrosurgical pencil eliminates the risk of cross contamination and provides known electrosurgical performance in each surgery.Â
Surgical tool that is used with an electrosurgical unit (ESU) in a laparoscopic procedure to cut, coagulate and dissect tissue. This laparoscopic electrode delivers energy with minimal thermal spread for precise delivery, leading to safer, faster surgical outcomes in general, gynecological, gall bladder and hernia laparoscopy.Â
Specifications:
Type: Monopolar / Bipolar (specify as applicable)
Shaft Length: 330 mm / 450 mm (common OT sizes)
Shaft Diameter: 5 mm
Tip Style: Hook, spatula, or L hook (per procedure requirement)
Insulation: Full length shaft insulation to prevent stray current leakage
Material: Surgical grade stainless steel
Compatibility: Standard electrosurgical generators (most ESU brands)
Sterilization: Autoclavable, reusable up to multiple sterilization cycles
Usage Type: Reusable / Single use options available
A long lasting instrument for electrosurgery, linking the generator to a monopolar handpiece for the administration of a steady current for cutting and coagulation during surgery. The monopolar cable 4mm female to male connector provides a dependable connection between compatible electrosurgical equipment.Â
Specifications:
Connector type:4mm female to maleÂ
Conductor: Low resistance copper core
Insulation:Silicone, autoclavableÂ
Standard length:3 metres (also available in 2 m and 4 m)Â
Compatibility: Standard monopolar electrosurgical generators
Sterilization: Autoclave safe, reusable
Build: Reinforced strain relief at both ends of connectors
A monopolar cable 8mm male 4.8mm female connector can be used multiple times to join an electrosurgical pencil or handpiece to an electrosurgical generator to pass current between them during surgical operations to cut and coagulate tissue.Â
Specifications:
Connector type:8mm male (generator end) to 4.8mm Female (handpiece end)Â
Compatibility:Connects to standard 8mm output sockets on generators and 4.8mm banana style plug handpieces/pencilsÂ
Insulation:Silicone body, flexible and tear resistantÂ
Sterilization: Autoclavable, suitable for repeated steam sterilization cycles
Conductor:Low resistance to deliver consistent energyÂ
Build:Reinforced strain relief in both connector joints to minimise wear caused by repeated use
Use case: General surgery, minor procedures, OT and clinic settings
Reusability:Not designed for single use but designed for multiple use and sterilisation
A durable, autoclavable bipolar cable that links bipolar forceps to the electrosurgical generator, with a reusable silicone bipolar cable and an American design made for repeated use in the hectic surgical environment.Â
Specifications:
Type:Reusable Bipolar (RBC) Cable from American Standard
Connector Style:American pin type (forceps end and generator end)Â
A safe, stable, long lasting, autoclavable grounding cable used to provide connections between the patient return plate and the electrosurgical unit (ESU) during surgery. Made for reuse at the hospital, the reusable silicone earth patient plate cable is a more cost effective and longer lasting replacement for disposable cables.Â
Specifications:
Material:Medical grade siliconeÂ
Type:Reusable (not single use)Â
Sterilization:Autoclave compatibleÂ
Connector:Standard ESU compatible connector endsÂ
Length: 3–5 meters (longer lengths on request)Â
Conductivity: Stable continuity under continuous load
Durability:Reinforced strain relief at connector points
Operating Conditions: Heat and humidity resistant
Use Case:ESU grounding for electrocautery proceduresÂ
Compatibility:Common and compatible with the most popular brands used in hospitals and clinics in Pakistan
Reviews