A stable and safe return cable for the patient return plates to the electrosurgical generators for monopolar surgical procedures. The bipolar earth plate cable 6mm provides a stable connection between the patient return plate and the electrosurgical generator.Â
Specifications:
Conductor size:6mm earth conductor coreÂ
Insulation:High grade silicone with heat and autoclave resistanceÂ
Conductor material:Stable current return with low resistance copperÂ
Connector type:Commonly used electrosurgical generator standard fittingsÂ
Jacket:Kink resistant outer sheath that is flexible
Sterilization:Autoclavable and can be used repeatedly in hospitals for hospital sterilisation cyclesÂ
Reusability: Reusable across multiple procedures with proper maintenance
Application:Monopolar electrosurgery units for hospitals, surgical clinics, OT
One time grounding pad for safe, reliable return of current for monopolar electrosurgical procedures. Designed to be used every time with every patient in hospitals and clinics, the disposable earth plate bipolar provides a practical option without compromising performance.Â
Specifications:
Type: Disposable, single use return electrode pad
Compatibility: Uses typical monopolar electrosurgical generators, including REM (return electrode monitoring) generatorsÂ
Adhesive: Safe for skin and leaves no residue on removal
Conductive layer: Even gel distribution for consistent impedance and reduced burn risk
Packaging: Sterile and individually sealed until opened
Shelf life: Will store for long periods of time, ideal for bulk stockers such as hospitals and distributors.Â
Application area: Suitable for adult and pediatric use on clean, well vascularized skin
Power stability: Smooth operation even when the power is irregular from alternative power supplies
A single use patient return electrode (earth plate) designed to function with ValleyLab compatible electrosurgical units. It has a skin friendly conductive adhesive layer that distributes current evenly over the contact area, leaving the patient's skin protected and keeping the electrosurgical circuit safe. It is disposable and doesn't pose the risk of cross contamination from reusable plates and doesn't require any cleaning or sterilisation between patients. A disposable earth plate ValleyLab connector provides the required connection for compatible electrosurgical units.Â
A one time surgical instrument for cutting and coagulating tissue during surgery, the disposable electrosurgical pencil eliminates the risk of cross contamination and provides known electrosurgical performance in each surgery.Â
The monopolar cable 8mm male 4mm female is a combination of an 8mm generator output and a 4mm handpiece input. Designed for daily use with reliable conductivity and autoclave safe insulation.Â
An autoclaveable reusable electrosurgical pencil that can be reused in surgery. Designed for repeated sterilization without sacrificing cutting and coagulation capabilities, it is a cost effective option for medical facilities that are utilizing procedures on a consistent basis, such as hospitals and clinics.Â
Specifications:
Type: Reusable electrosurgical (cautery) pencil
Sterilization: Autoclavable, rated for multiple steam sterilization cycles
Connector:Standard electrosurgical generator connector (will fit into typical hospital ESU systems)Â
Switch modes:Dual or triple mode finger switch (cut/coagulation/blend)Â
Electrode tip:Self releasing and replaceable separately from handleÂ
Body material:Heat resistant, autoclave safe housingÂ
Grip design:Ergonomic, contoured for use during longer proceduresÂ
Cable length:Standard length as per OT setups (please specify exact length with Capasee)
Intended use: Electrosurgical procedures, such as general surgery, gynecological surgery, ENT surgery, and other procedures.
A durable, autoclavable bipolar cable that links bipolar forceps to the electrosurgical generator, with a reusable silicone bipolar cable and an American design made for repeated use in the hectic surgical environment.Â
Specifications:
Type:Reusable Bipolar (RBC) Cable from American Standard
Connector Style:American pin type (forceps end and generator end)Â
The bipolar forceps are powered by a reusable, autoclavable bipolar cable, which runs directly from the bipolar forceps to a European standard electrosurgical generator. Medical grade silicone insulation allows it to be washed and sterilized repeatedly, and it is a long lasting, cost effective solution over disposable cables. A reusable silicone bipolar cable European standard connector provides a dependable connection for repeated surgical use.Â
Specifications:
Connector type: European standard bipolar connector
Material:Medical grade silicone materialÂ
Sterilization:Safe for repeated autoclave cycles (may be steam autoclave safe)Â
Usage:Re useable (multi cycle, not single use)Â
Compatibility:Compatible with European style bipolar generators and bipolar forcepsÂ
Cable design:Flexible, kink resistant body for easy handling in the surgical field
Connector housing: Sealed against steam penetration to protect internal contacts from corrosion
Reviews