Skip to content
  • .
Facebook Instagram Linkedin
Capasee
  • Home
  • About Capasee
  • Shop
  • Categories

    Capasee Products

    Stabilizer
    UPS
    Best Selling
    Solar Charger Controller
    Solar
    Best selling
    Electro Surgical Unit
    Best selling
    Ventilator
    Surgical Instruments & Equipment
    Anesthesia Machine
    Bipap/c-pap Machine
    Defibrillator
    Fetal monitor
    Sugical Knife
    Demo

    Capasee Products

    Hospital Furniture
    Shadowless operating light
    Hot Product
    Baby warmer
    ECG Machine
    Suction Machine 
    Baby Incubator
    Ultrasound
    Patient Monitor
    Phototherapy light
    Hot Product
    Infant Care
    Electro Surgical Unit Standard Accessories
    Favor for You
    New Product 2
    Best Selling
  • Our Blogs
  • Contact us
Capasee
₨ 12,500 1 Cart
“Reusable Silicone Earth Patient Plate 6mm Connector” has been added to your basket. Checkout
Martin Bipolar Cable
Click to enlarge
Home Electrosurgical Accessories Martin Bipolar Cable
Bipolar Cable Bowa
Bipolar Cable Bowa Medical ₨ 9,500
Back to products
Bipolar Earth Plate Cable 6mm
Bipolar Earth Plate Cable 6mm ₨ 8,500

Martin Bipolar Cable

₨ 9,500

A long, reusable Martin bipolar cable to deliver bipolar current to bipolar forceps for accurate tissue coagulation during surgery. Designed for repeated autoclave sterilisation and everyday OT use. 

Specifications:

  • Connector type: Martin style bipolar plug 
  • Cable length: 2.5 m / 3 m (standard options)
  • Insulation: Silicone jacket
  • Conductor: Copper core, low resistance braid
  • Sterilization: Autoclavable, standard hospital cycles 
  • Reusability: Multi use, reusable cable
  • Compatible with: Generators with Martin standard bipolar connectors 
  • Application: Aesthetic surgery, ear, nose, throat, obstetrics, laparoscopy

Indicative price — contact us for today’s exact price, stock and delivery for your location.

WhatsApp for Final Price & Delivery
Compare
Add to wishlist
Category: Electrosurgical Accessories
Share:
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

Martin Bipolar Cable: Reliable Connection for Bipolar Electrosurgery

A Martin bipolar cable is the cable used for bipolar forceps or bipolar instruments to transfer the current required to precisely coagulate tissue from an electrosurgical generator. Designed for Pakistani surgeons, OT technologists, and hospital procurement personnel, it serves as a reliable connection between the instrument and the generator in general surgery, ENT, gynecology, and laparoscopic surgeries.

Key Features and Benefits

  • Martin style connector fitting: Compatible with the standard Martin plug configuration on many bipolar generators, allowing operating room personnel to change instruments from case to case without having to search for adapters. The Martin bipolar cable provides the required connector configuration for this setup. 
  • Silicone insulated cable body: Silicone won’t break down as often as standard rubber jackets in hospitals in Pakistan that may be operating several cycles of sterilization per day. This makes the Martin bipolar cable suitable for repeated OT use. 
  • Low electrical resistance core: A tighter, higher grade copper braid provides consistent energy delivery, thus minimizing the risk of incomplete coagulation and the need for the surgeon to repeat a step during the procedure.
  • Reinforced strain relief at both ends: The most stressed area of OT equipment used on a daily basis is the connection between the cable and the connector. Further reinforced moulding here increases service life against continuous plugging, unplugging, and autoclaving operations. This construction helps the Martin bipolar cable withstand routine handling. 
  • Standard cable lengths (2.5m and 3m): Long enough to go from generator to table but not enough to cross the sterile field so as to minimise the chance of accidental contamination when setting up. These lengths make the Martin bipolar cable practical for typical operating room layouts. 
  • Autoclavable up to standard hospital cycles: There is no need for workarounds with chemicals. All cables are inserted into the existing sterilisation process along with other reusable instruments. The Martin bipolar cable can therefore fit into established reusable instrument workflows. 

These are all actual points of friction that the OT staff has during a working day, not something on a datasheet. 

Who Should Buy This Cable

Hospitals and clinics that perform electrosurgical procedures every day should keep a supply of these cables on hand, as they don’t want to be left to deal with a cable failure in the middle of an operation. In urban areas where there is frequent voltage fluctuation, which is common in many parts of Pakistan, the Martin bipolar cable is constructed with thicker insulation, as more stress is placed on them when the generator output fluctuates.

A quality checked source is also essential for distributors providing to general and private hospitals or teaching hospitals and day care surgery centres, as reordering delays have a direct impact on the hospital’s surgical schedule. It’s typically biomedical engineers who order cables when they become damaged at the connector, and when the engineer is local, the cycle is that much faster.

Why Choose Capasee Electro Medical Engineering?

Capasee Electro Medical Engineering has been in the field for years and has been supplying and installing electrosurgical accessories directly to biomedical departments in hospitals and clinics to understand what really goes wrong in hospitals. That hands on experience determines what cables are ordered and recommended. 

All Martin bipolar cables dispatched are tested for connector fit and continuity, and Capasee offers after sales support for any questions of compatibility or replacement, leaving hospitals not left waiting when equipment fails mid week.

Frequently Asked Questions

What is the main use of a Martin bipolar cable?

It is used to link bipolar forceps or bipolar instruments to an electrosurgical generator to allow the current to flow through them for tissue coagulation during surgery.

Are Martin bipolar cables reusable?

Yes, they are reusable and built to be used over and over again between procedures.

How do you sterilize them?

The standard procedure is to autoclave them in the hospital, according to the standard hospital autoclave procedure already implemented with other reusable OT instruments.

What generators are they compatible with?

Cables containing the Martin style connector will fit generators designed for that type of plug; please consult the type of connector on your generator before purchasing.

Do they need a patient return electrode (grounding pad)?

They are bipolar, so there’s no need to use a separate patient return electrode as there is in monopolar setups.

Can the cable be autoclaved? 

Yes, the silicone insulated construction is suitable for a normal autoclave cycle.

What procedures use this cable? 

This cable is used in general surgery, ENT, gynecological, and laparoscopic surgeries with bipolar electrosurgical instruments.

Get Your Martin Bipolar Cable

Please call Capasee Electro Medical Engineering to confirm stock and connector compatibility with your generator and to order your Martin bipolar cable. Call now to get your pricing and delivery hours anywhere in Pakistan.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Martin Bipolar Cable” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery
[Shipping policy to be updated]

Related products

Bipolar Cable Bowa
Compare

Bipolar Cable Bowa Medical

Electrosurgical Accessories
₨ 9,500
Designed for hospitals and clinics that require a reliable, easy to sterilize cable for everyday theatre use, this reusable bipolar cable BOWA is compatible with bipolar forceps and instruments with BOWA electrosurgical generators.

Specifications:

  • Compatibility: BOWA electrosurgical generator systems (bipolar output) 
  • Connector type: Special bipolar pin connector, perfectly matched to BOWA socket 
  • Core material: Low resistance copper conductor 
  • Insulation: Reinforced silicone sheathing 
  • Sterilization: Autoclavable, suitable for repeated steam sterilizations
  • Reusability: Multi use and reprocessable, not single use
  • Cable design: Flexible, kink resistant, consistent length for reliable field handling
  • Application: Bipolar electrosurgery (no grounding pad/neutral electrode is needed) 
  • Intended use setting: Surgical theatres, clinical surgery, biomedical in hospitals
Add to wishlist
Add to basket
Quick view
Disposable Earth Plate ValleyLab Connector
Compare

Disposable Earth Plate ValleyLab Connector

Electrosurgical Accessories
₨ 1,800
A single use patient return electrode (earth plate) designed to function with ValleyLab compatible electrosurgical units. It has a skin friendly conductive adhesive layer that distributes current evenly over the contact area, leaving the patient's skin protected and keeping the electrosurgical circuit safe. It is disposable and doesn't pose the risk of cross contamination from reusable plates and doesn't require any cleaning or sterilisation between patients. A disposable earth plate ValleyLab connector provides the required connection for compatible electrosurgical units. 

Specifications:

  • Type: Disposable patient return electrode (earth plate/grounding pad) 
  • Connector: Connects easily to the electrosurgical unit for use with the ValleyLab
  • Compatibility: ValleyLab / Covidien type electrosurgical generators
  • Application: Monopolar electrosurgery in general surgery, gynecology, orthopedics, and more 
  • Conductive layer: Hypoallergenic hydrogels with adhesive properties that ensure uniform current dispersion 
  • Backing material: Soft, flexible foam 
  • Patient group: Adult (available in other sizes on request)
  • Cable: Pre attached insulated cable with a secure, snug fit connector
  • Usage: Single use only, discard after each procedure
  • Packaging: Individually sealed pouch to keep the adhesive fresh 
  • Storage: Store in a cool, dry place away from direct sunlight
Add to wishlist
Add to basket
Quick view
Compare

Disposable Electrosurgical Pencil

Electrosurgical Accessories
₨ 2,500
A one time surgical instrument for cutting and coagulating tissue during surgery, the disposable electrosurgical pencil eliminates the risk of cross contamination and provides known electrosurgical performance in each surgery. 

Specifications:

  • Type: Single use, disposable 
  • Sterilization: Factory sterilized (EO sterilized), individually sealed 
  • Electrode Tip: Stainless steel, standard blade tip
  • Activation: Finger tip switch, dual mode (cut/coagulation)
  • Cable Length: Standard 3 metres (customizable on request)
  • Connector: Universal, compatible with most standard electrosurgical generators 
  • Grip: Pencil lightweight ergonomic handle 
  • Packaging: Individually packed, peel open sterile pouch
  • Shelf Life: 3 years from date of manufacture 
  • Usage: General surgery, gynecology, ENT, and dermatology procedures.
Add to wishlist
Add to basket
Quick view
Monopolar Cable 8mm Male 4mm Female – Electrosurgery
Compare

Monopolar Cable 8mm Male 4mm Female – Electrosurgery

Electrosurgical Accessories
₨ 9,500
The monopolar cable 8mm male 4mm female is a combination of an 8mm generator output and a 4mm handpiece input. Designed for daily use with reliable conductivity and autoclave safe insulation. 

Specifications:

  • Connector type: 8mm male to 4mm female 
  • Conductor: High grade copper (HRC) core 
  • Insulation: Medical grade silicone, autoclavable
  • Shielding: Full, reduces nearby monitor EMI interference
  • Strain relief: Reinforced at both connector ends
  • Compatibility: Standard monopolar electrosurgery generators and handpieces will work.
  • Use: Cutting and coagulation during surgical procedures
  • Reusability: Sterilizable, suited for repeated OT cycles
Add to wishlist
Add to basket
Quick view
Patient Plate
Compare

Patient Plate | Electrosurgical Return Plate for Surgery

Electrosurgical Accessories
₨ 6,500
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.

Specifications:

  • Type: Single use, disposable return electrode / grounding pad
  • Material: Latex free, hypoallergenic conductive material
  • Adhesive: Skin safe gel adhesive for secure, stable contact
  • Design: Split pad, contact quality monitoring compatible
  • Compatibility: Works with standard monopolar electrosurgical generators
  • Packaging: Individually sterile packed
  • Use case: General surgery, gynecological, ENT, and laparoscopic surgeries
  • Shelf stability: Performs reliably under standard hospital storage and power conditions
Add to wishlist
Add to basket
Quick view
Compare

Reusable Electrosurgical Pencil

Electrosurgical Accessories
₨ 8,500
An autoclaveable reusable electrosurgical pencil that can be reused in surgery. Designed for repeated sterilization without sacrificing cutting and coagulation capabilities, it is a cost effective option for medical facilities that are utilizing procedures on a consistent basis, such as hospitals and clinics. 

Specifications:

  • Type: Reusable electrosurgical (cautery) pencil
  • Sterilization: Autoclavable, rated for multiple steam sterilization cycles
  • Connector: Standard electrosurgical generator connector (will fit into typical hospital ESU systems) 
  • Switch modes: Dual or triple mode finger switch (cut/coagulation/blend) 
  • Electrode tip: Self releasing and replaceable separately from handle 
  • Body material: Heat resistant, autoclave safe housing 
  • Grip design: Ergonomic, contoured for use during longer procedures 
  • Cable length: Standard length as per OT setups (please specify exact length with Capasee)
  • Intended use: Electrosurgical procedures, such as general surgery, gynecological surgery, ENT surgery, and other procedures.
  • Sold by: Capasee Electro Medical Engineering
Add to wishlist
Add to basket
Quick view
Compare

Reusable Silicone Bipolar Cable European

Electrosurgical Accessories
₨ 9,500
The bipolar forceps are powered by a reusable, autoclavable bipolar cable, which runs directly from the bipolar forceps to a European standard electrosurgical generator. Medical grade silicone insulation allows it to be washed and sterilized repeatedly, and it is a long lasting, cost effective solution over disposable cables. A reusable silicone bipolar cable European standard connector provides a dependable connection for repeated surgical use. 

Specifications:

  • Connector type: European standard bipolar connector
  • Material: Medical grade silicone material 
  • Sterilization: Safe for repeated autoclave cycles (may be steam autoclave safe) 
  • Usage: Re useable (multi cycle, not single use) 
  • Compatibility: Compatible with European style bipolar generators and bipolar forceps 
  • Cable design: Flexible, kink resistant body for easy handling in the surgical field
  • Connector housing: Sealed against steam penetration to protect internal contacts from corrosion
Add to wishlist
Add to basket
Quick view
Reusable Silicone Earth Patient Plate Cable
Compare

Reusable Silicone Earth Patient Plate Cable – Medical ESU Grounding

Electrosurgical Accessories
₨ 8,500
A safe, stable, long lasting, autoclavable grounding cable used to provide connections between the patient return plate and the electrosurgical unit (ESU) during surgery. Made for reuse at the hospital, the reusable silicone earth patient plate cable is a more cost effective and longer lasting replacement for disposable cables. 

Specifications:

  • Material: Medical grade silicone 
  • Type: Reusable (not single use) 
  • Sterilization: Autoclave compatible 
  • Connector: Standard ESU compatible connector ends 
  • Length: 3–5 meters (longer lengths on request) 
  • Conductivity: Stable continuity under continuous load
  • Durability: Reinforced strain relief at connector points
  • Operating Conditions: Heat and humidity resistant
  • Use Case: ESU grounding for electrocautery procedures 
  • Compatibility: Common and compatible with the most popular brands used in hospitals and clinics in Pakistan
Add to wishlist
Add to basket
Quick view
    Capasee
    Facebook Instagram Linkedin

    Quick Links

    • Home
    • About Us
    • Shop
    • Our Blogs
    • Contact Us
    • Return Policy

    Contact Us

    Email

    [email protected]

    Phone

    +92 300 8474110
    0423 750 4447

    Address

    3/4 Husnain Street, Shah Kamal Road, Lahore - Pakistan.

    Certification

    Capasee Worldwide
    international Accreditation Form
    IAS Certification of Capasee
    ISO 9001 Certification of Capasee
    RICI Certification of Capasee
    IAS Certification of Capasee
    Capasee service at Germany
    Capasee service at Pakistan
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Capasee service
    Copyright 2026 Capasee.com All Rights Reserved.
    Close
    Shopping cart
    Close