Reusable Forceps. Tip Size: 0.5mm, 1mm, 1.5mm, 2mm. Forceps length: 12cm, 15cm, 18cm, 20cm, 22cm, 24cm.
“Bipolar Cable Bowa Medical” has been added to your basket. Checkout
European Bipolar Forceps Straight
₨ 14,500
Indicative price — contact us for today’s exact price, stock and delivery for your location.
WhatsApp for Final Price & Delivery
Category: Electrosurgical Accessories
Description
Reviews (0)
Be the first to review “European Bipolar Forceps Straight” Cancel reply
Shipping & Delivery
[Shipping policy to be updated]
Related products
Bipolar Earth Plate Cable 6mm
₨ 8,500
A stable and safe return cable for the patient return plates to the electrosurgical generators for monopolar surgical procedures. The bipolar earth plate cable 6mm provides a stable connection between the patient return plate and the electrosurgical generator.Â
Specifications:
- Conductor size: 6mm earth conductor coreÂ
- Insulation: High grade silicone with heat and autoclave resistanceÂ
- Conductor material: Stable current return with low resistance copperÂ
- Connector type: Commonly used electrosurgical generator standard fittingsÂ
- Jacket: Kink resistant outer sheath that is flexible
- Sterilization: Autoclavable and can be used repeatedly in hospitals for hospital sterilisation cyclesÂ
- Reusability: Reusable across multiple procedures with proper maintenance
- Application: Monopolar electrosurgery units for hospitals, surgical clinics, OT
Bipolar Forceps Cable | Electrosurgical Unit Accessory
₨ 8,500
A connecting accessory that can be used in hospitals and surgical centres with electrosurgical generators and is reliable. Designed for reliable current transfer, safety, and long term use with repeated sterilization cycles in a Pakistani OT setting using an electrosurgical unit accessory.Â
Specifications:
- Material: Medical grade silicone insulated with a copper conductor core for safety.
- Compatibility: Standard and generator specific connectors are both compatible.
- Sterilization: Autoclavable, steam sterilization compatible
- Length options: 2m / 3m / 5m
- Connector type: Standard OT compatible plug (universal or brand specific on request)
- Durability: Reinforced strain relief at connector ends to eliminate wire fatigue
- Use environment: Hospital OTs, Clinics, Surgical Centres
- Warranty: 1 to 2 years
Bipolar Hand Controller
₨ 8,500
Switching accessories for bipolar electrosurgical generators with hand operation. It allows the surgeon to control coagulation or cutting from the hand piece without the need for a foot pedal, allowing for a more focused operation with a reliable bipolar hand controller solution.Â
Specifications:
- Type: Bipolar hand activated control switch
- Compatibility: Standard bipolar electrosurgical generator interface
- Activation Mode: Manual push button (coagulation/cutting)
- Housing Material: Medical grade, autoclavable
- Sterilization: Autoclave compatible
- Cable: Durable, flexible, high cycle rated jacket
- Power Stability: Reliable performance under fluctuating voltage conditions
- Grip Design: Lightweight, ergonomic for extended procedure use
- Manufacturer: Capasee Electro Medical Engineering
Disposable Earth Plate Bipolar
₨ 1,800
One time grounding pad for safe, reliable return of current for monopolar electrosurgical procedures. Designed to be used every time with every patient in hospitals and clinics, the disposable earth plate bipolar provides a practical option without compromising performance.Â
Specifications:
- Type: Disposable, single use return electrode pad
- Compatibility: Uses typical monopolar electrosurgical generators, including REM (return electrode monitoring) generatorsÂ
- Adhesive: Safe for skin and leaves no residue on removal
- Conductive layer: Even gel distribution for consistent impedance and reduced burn risk
- Packaging: Sterile and individually sealed until opened
- Shelf life: Will store for long periods of time, ideal for bulk stockers such as hospitals and distributors.Â
- Application area: Suitable for adult and pediatric use on clean, well vascularized skin
- Power stability: Smooth operation even when the power is irregular from alternative power supplies
Disposable Earth Plate ValleyLab Connector
₨ 1,800
A single use patient return electrode (earth plate) designed to function with ValleyLab compatible electrosurgical units. It has a skin friendly conductive adhesive layer that distributes current evenly over the contact area, leaving the patient's skin protected and keeping the electrosurgical circuit safe. It is disposable and doesn't pose the risk of cross contamination from reusable plates and doesn't require any cleaning or sterilisation between patients. A disposable earth plate ValleyLab connector provides the required connection for compatible electrosurgical units.Â
Specifications:
- Type: Disposable patient return electrode (earth plate/grounding pad)Â
- Connector: Connects easily to the electrosurgical unit for use with the ValleyLab
- Compatibility: ValleyLab / Covidien type electrosurgical generators
- Application: Monopolar electrosurgery in general surgery, gynecology, orthopedics, and moreÂ
- Conductive layer: Hypoallergenic hydrogels with adhesive properties that ensure uniform current dispersionÂ
- Backing material: Soft, flexible foamÂ
- Patient group: Adult (available in other sizes on request)
- Cable: Pre attached insulated cable with a secure, snug fit connector
- Usage: Single use only, discard after each procedure
- Packaging: Individually sealed pouch to keep the adhesive freshÂ
- Storage: Store in a cool, dry place away from direct sunlight
Monopolar Cable 4mm Female to Male Connector
₨ 9,500
A long lasting instrument for electrosurgery, linking the generator to a monopolar handpiece for the administration of a steady current for cutting and coagulation during surgery. The monopolar cable 4mm female to male connector provides a dependable connection between compatible electrosurgical equipment.Â
Specifications:
- Connector type: 4mm female to maleÂ
- Conductor: Low resistance copper core
- Insulation: Silicone, autoclavableÂ
- Standard length: 3 metres (also available in 2 m and 4 m)Â
- Compatibility: Standard monopolar electrosurgical generators
- Sterilization: Autoclave safe, reusable
- Build: Reinforced strain relief at both ends of connectors
- Sheathing: Flexible, kink resistant
Monopolar Cable 8mm Male 4.8mm Female Connector
₨ 9,500
A monopolar cable 8mm male 4.8mm female connector can be used multiple times to join an electrosurgical pencil or handpiece to an electrosurgical generator to pass current between them during surgical operations to cut and coagulate tissue.Â
Specifications:
- Connector type: 8mm male (generator end) to 4.8mm Female (handpiece end)Â
- Compatibility: Connects to standard 8mm output sockets on generators and 4.8mm banana style plug handpieces/pencilsÂ
- Insulation: Silicone body, flexible and tear resistantÂ
- Sterilization: Autoclavable, suitable for repeated steam sterilization cycles
- Conductor: Low resistance to deliver consistent energyÂ
- Build: Reinforced strain relief in both connector joints to minimise wear caused by repeated use
- Use case: General surgery, minor procedures, OT and clinic settings
- Reusability: Not designed for single use but designed for multiple use and sterilisation
Patient Plate | Electrosurgical Return Plate for Surgery
₨ 6,500
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
- Type: Single use, disposable return electrode / grounding pad
- Material: Latex free, hypoallergenic conductive material
- Adhesive: Skin safe gel adhesive for secure, stable contact
- Design: Split pad, contact quality monitoring compatible
- Compatibility: Works with standard monopolar electrosurgical generators
- Packaging: Individually sterile packed
- Use case: General surgery, gynecological, ENT, and laparoscopic surgeries
- Shelf stability: Performs reliably under standard hospital storage and power conditions

Reviews
There are no reviews yet.