Reusable Forceps Non Stick. Tip Size: 0.5mm, 1mm, 1.5mm, 2mm. Forceps length: 12cm, 15cm, 18cm, 20cm, 22cm, 24cm.
“Reusable Silicone Patient Plate – Valleylab Connector” has been added to your basket. Checkout
European Bipolar Forceps Straight – Non Stick
₨ 24,500
Indicative price — contact us for today’s exact price, stock and delivery for your location.
WhatsApp for Final Price & Delivery
Category: Electrosurgical Accessories
Description
Reviews (0)
Be the first to review “European Bipolar Forceps Straight – Non Stick” Cancel reply
Shipping & Delivery
[Shipping policy to be updated]
Related products
Bipolar Cable Bowa Medical
₨ 9,500
Designed for hospitals and clinics that require a reliable, easy to sterilize cable for everyday theatre use, this reusable bipolar cable BOWA is compatible with bipolar forceps and instruments with BOWA electrosurgical generators.
Specifications:
- Compatibility: BOWA electrosurgical generator systems (bipolar output)Â
- Connector type: Special bipolar pin connector, perfectly matched to BOWA socketÂ
- Core material: Low resistance copper conductorÂ
- Insulation: Reinforced silicone sheathingÂ
- Sterilization: Autoclavable, suitable for repeated steam sterilizations
- Reusability: Multi use and reprocessable, not single use
- Cable design: Flexible, kink resistant, consistent length for reliable field handling
- Application: Bipolar electrosurgery (no grounding pad/neutral electrode is needed)Â
- Intended use setting: Surgical theatres, clinical surgery, biomedical in hospitals
Disposable Earth Plate ValleyLab Connector
₨ 1,800
A single use patient return electrode (earth plate) designed to function with ValleyLab compatible electrosurgical units. It has a skin friendly conductive adhesive layer that distributes current evenly over the contact area, leaving the patient's skin protected and keeping the electrosurgical circuit safe. It is disposable and doesn't pose the risk of cross contamination from reusable plates and doesn't require any cleaning or sterilisation between patients. A disposable earth plate ValleyLab connector provides the required connection for compatible electrosurgical units.Â
Specifications:
- Type: Disposable patient return electrode (earth plate/grounding pad)Â
- Connector: Connects easily to the electrosurgical unit for use with the ValleyLab
- Compatibility: ValleyLab / Covidien type electrosurgical generators
- Application: Monopolar electrosurgery in general surgery, gynecology, orthopedics, and moreÂ
- Conductive layer: Hypoallergenic hydrogels with adhesive properties that ensure uniform current dispersionÂ
- Backing material: Soft, flexible foamÂ
- Patient group: Adult (available in other sizes on request)
- Cable: Pre attached insulated cable with a secure, snug fit connector
- Usage: Single use only, discard after each procedure
- Packaging: Individually sealed pouch to keep the adhesive freshÂ
- Storage: Store in a cool, dry place away from direct sunlight
Disposable Monopolar Earth Plate – Patient Return Electrode
₨ 1,800
One time patient return electrode in monopolar electrosurgery to safely complete the electrical circuit, directing current away from the patient's body and preventing burns during surgical procedures. The disposable monopolar earth plate provides a safe patient return path during the procedure.Â
Specifications:
- Type: Disposable, non sterile/sterile (based on the model)Â
- Design: Split pad or solid pad configuration
- Adhesive: Consistent skin contact provided by the conductive hydrogel layer
- Material: Latex free, skin safe backingÂ
- Compatibility: Standard monopolar electrosurgical generators (general surgery, gynecology, urology, ENT)Â
- Sizes: Adult and pediatric options available
- Packaging: Individually packed for hygiene and ease of useÂ
- Shelf life: According to the manufacturer's batch (usually 2 to 3 years from manufacturing date)Â
- Usage: One patient, one procedure, no reuse
ECG Electrodes
₨ 4,500
Single use electrodes for the recording of the ECG, for stress tests, and for continuous cardiac monitoring, which are attached by adhesive. Stable skin contact and low noise signal transmission for hospital, clinic or home care with reliable ECG electrodes.Â
Specifications
Sensing element: Silver/silver chloride (Ag/AgCl) Type: Disposable, single use Adhesive: Medical grade hydrogel Backing material: Hypoallergenic foam or cloth Packaging: Individually sealed, maintain gel's moisture until use Application: 12 lead ECG, stress testing, Holter monitoring Compatibility: Standard ECG machines and monitoring leads Storage condition: Cool, dry place away from direct heat and sunlight Shelf life: 1 to 3 years from manufacture (refer to batch label) Skin suitability: Suitable for adult and pediatric use (confirm sizing for pediatric patients)Laparoscopic Electrode for Electrosurgical Use
₨ 12,500
Surgical tool that is used with an electrosurgical unit (ESU) in a laparoscopic procedure to cut, coagulate and dissect tissue. This laparoscopic electrode delivers energy with minimal thermal spread for precise delivery, leading to safer, faster surgical outcomes in general, gynecological, gall bladder and hernia laparoscopy.Â
Specifications:
- Type: Monopolar / Bipolar (specify as applicable)
- Shaft Length: 330 mm / 450 mm (common OT sizes)
- Shaft Diameter: 5 mm
- Tip Style: Hook, spatula, or L hook (per procedure requirement)
- Insulation: Full length shaft insulation to prevent stray current leakage
- Material: Surgical grade stainless steel
- Compatibility: Standard electrosurgical generators (most ESU brands)
- Sterilization: Autoclavable, reusable up to multiple sterilization cycles
- Usage Type: Reusable / Single use options available
- Connector: Standard ESU cable connector
Patient Plate | Electrosurgical Return Plate for Surgery
₨ 6,500
The patient plate is an electrode that is only used once in electrosurgery to help safely complete the electrical circuit between the patient and the electrosurgical generator to prevent burns by allowing the current to pass back along a large, controlled contact area instead of through unintended body tissue.
Specifications:
- Type: Single use, disposable return electrode / grounding pad
- Material: Latex free, hypoallergenic conductive material
- Adhesive: Skin safe gel adhesive for secure, stable contact
- Design: Split pad, contact quality monitoring compatible
- Compatibility: Works with standard monopolar electrosurgical generators
- Packaging: Individually sterile packed
- Use case: General surgery, gynecological, ENT, and laparoscopic surgeries
- Shelf stability: Performs reliably under standard hospital storage and power conditions
Reusable Silicone Bipolar Cable European
₨ 9,500
The bipolar forceps are powered by a reusable, autoclavable bipolar cable, which runs directly from the bipolar forceps to a European standard electrosurgical generator. Medical grade silicone insulation allows it to be washed and sterilized repeatedly, and it is a long lasting, cost effective solution over disposable cables. A reusable silicone bipolar cable European standard connector provides a dependable connection for repeated surgical use.Â
Specifications:
- Connector type: European standard bipolar connector
- Material: Medical grade silicone materialÂ
- Sterilization: Safe for repeated autoclave cycles (may be steam autoclave safe)Â
- Usage: Re useable (multi cycle, not single use)Â
- Compatibility: Compatible with European style bipolar generators and bipolar forcepsÂ
- Cable design: Flexible, kink resistant body for easy handling in the surgical field
- Connector housing: Sealed against steam penetration to protect internal contacts from corrosion
Reusable Silicone Patient Plate – Valleylab Connector
₨ 12,500
Autoclavable reusable silicone patient plate that can be directly used with Valleylab compatible electrosurgical generators. Designed to replace one time use adhesive pads with a long life, gel free system for high volume OT use.Â
Specifications:
- Type: Reusable silicone patient return plate (non adhesive)
- Connector: Valleylab style, direct plug in (adapter not required)Â
- Material: Medical grade conductive siliconeÂ
- Gel requirement: None
- Sterilization: Autoclavable / chemically sterilizableÂ
- Cable length: 3 metres (standard)Â
- Reusability: Multiple use, clean between procedures
- Compatibility: Valleylab and Valleylab compatible electrosurgical unitsÂ
- Waste impact: Minimizes the waste of disposable pads and biomedical waste