Reusable Forceps. Tip Size: 0.5mm, 1mm, 1.5mm, 2mm. Forceps length: 15cm, 18cm, 20cm, 22cm, 24cm.
“ESU Foot Switch for Electrosurgical Units | Foot Pedal Controller” has been added to your basket. Checkout
American Bipolar Forceps Bayonet
₨ 14,500
Indicative price — contact us for today’s exact price, stock and delivery for your location.
WhatsApp for Final Price & Delivery
Category: Electrosurgical Accessories
Description
Reviews (0)
Be the first to review “American Bipolar Forceps Bayonet” Cancel reply
Shipping & Delivery
[Shipping policy to be updated]
Related products
Bipolar Electrosurgical Forceps
₨ 14,500
Surgical bipolar electrosurgical forceps that are reusable and precise for the controlled grasping and electrosurgical coagulation of tissue. Ideal for ENT, gynaecology, general surgery, and laparoscopy, where accurate hemostasis with minimal thermal spread is required using bipolar electrosurgical forceps.Â
Specifications:
- Material: Surgical grade stainless steel
- Tip Type: Straight/curved/bayonet (available in multiple configurations)
- Insulation: Fully insulated shaft to prevent current leakage
- Compatibility: Works with standard bipolar electrosurgical generators
- Sterilization: Autoclavable, reusable up to multiple sterilization cycles
- Length: Available in standard OT lengths (typically 180–200 mm)
- Handle: Ergonomic grip for reduced fatigue during long procedures
- Current Path: Bipolar (current flows only between tips, no patient return pad needed)
- Application: Cutting, coagulation, and precise hemostasis in open and minimally invasive surgery
Bipolar Foot Switch for Electrosurgical Use
₨ 9,500
Electrosurgical generators with a pedal operated control device activate the bipolar cutting and coagulation modes without the operator having to leave the operating field, making the bipolar foot switch an essential control accessory during surgical procedures.Â
Specifications:
- Type: Dual pedal bipolar activation (separate cut and coagulation controls)
- Housing: Sealed, spill and fluid resistant casing for OT environmentÂ
- Base: Non slip rubberized underside for stability on smooth floorsÂ
- Switch rating: High cycle microswitches used every day during clinical operationsÂ
- Connector: Standard compatibility with common electrosurgical generator ports
- Design: Low level, compact footprint to reduce OT floor clutter
- Build: Designed to operate for extended periods and multiple operations as needed
- Bipolar Foot Switch for Electrosurgical Use
Disposable Earth Plate Bipolar
₨ 1,800
One time grounding pad for safe, reliable return of current for monopolar electrosurgical procedures. Designed to be used every time with every patient in hospitals and clinics, the disposable earth plate bipolar provides a practical option without compromising performance.Â
Specifications:
- Type: Disposable, single use return electrode pad
- Compatibility: Uses typical monopolar electrosurgical generators, including REM (return electrode monitoring) generatorsÂ
- Adhesive: Safe for skin and leaves no residue on removal
- Conductive layer: Even gel distribution for consistent impedance and reduced burn risk
- Packaging: Sterile and individually sealed until opened
- Shelf life: Will store for long periods of time, ideal for bulk stockers such as hospitals and distributors.Â
- Application area: Suitable for adult and pediatric use on clean, well vascularized skin
- Power stability: Smooth operation even when the power is irregular from alternative power supplies
ESU Foot Switch for Electrosurgical Units | Foot Pedal Controller
₨ 9,500
A dual pedal foot control that is used in conjunction with electrosurgical units to turn them on and off during surgery without using your hands. The ESU foot switch is intended for repeated use in hospital and clinic operation theatres.Â
Specifications:
Type: Dual pedal (Cut / Coagulation) Compatibility: Standard ESU generator input, compatible with common electrosurgical units Housing: Sealed, spill and fluid resistant construction Base: Non slip rubber base for stable floor grip Cable: Reinforced, heavy duty cable resistant to cracking Connector: Standard pinout for direct plug in, no modification needed Activation: Firm tactile press point to prevent accidental triggering Usage environment: Designed for daily, high frequency OT useMonopolar Cable 8mm Male 4mm Female – Electrosurgery
₨ 9,500
The monopolar cable 8mm male 4mm female is a combination of an 8mm generator output and a 4mm handpiece input. Designed for daily use with reliable conductivity and autoclave safe insulation.Â
Specifications:
- Connector type: 8mm male to 4mm femaleÂ
- Conductor: High grade copper (HRC) coreÂ
- Insulation: Medical grade silicone, autoclavable
- Shielding: Full, reduces nearby monitor EMI interference
- Strain relief: Reinforced at both connector ends
- Compatibility: Standard monopolar electrosurgery generators and handpieces will work.
- Use: Cutting and coagulation during surgical procedures
- Reusability: Sterilizable, suited for repeated OT cycles
Reusable Electrosurgical Pencil
₨ 8,500
An autoclaveable reusable electrosurgical pencil that can be reused in surgery. Designed for repeated sterilization without sacrificing cutting and coagulation capabilities, it is a cost effective option for medical facilities that are utilizing procedures on a consistent basis, such as hospitals and clinics.Â
Specifications:
- Type: Reusable electrosurgical (cautery) pencil
- Sterilization: Autoclavable, rated for multiple steam sterilization cycles
- Connector: Standard electrosurgical generator connector (will fit into typical hospital ESU systems)Â
- Switch modes: Dual or triple mode finger switch (cut/coagulation/blend)Â
- Electrode tip: Self releasing and replaceable separately from handleÂ
- Body material: Heat resistant, autoclave safe housingÂ
- Grip design: Ergonomic, contoured for use during longer proceduresÂ
- Cable length: Standard length as per OT setups (please specify exact length with Capasee)
- Intended use: Electrosurgical procedures, such as general surgery, gynecological surgery, ENT surgery, and other procedures.
- Sold by: Capasee Electro Medical Engineering
Reusable Silicone Earth Patient Plate 6mm Connector
₨ 12,500
Return electrode, reusable, medical grade silicone, for use with electrosurgical units. It provides a safe electrical circuit completion for cautery and diathermy and is an autoclaveable alternative to disposable patient plates for a long lasting solution. The reusable silicone earth patient plate 6mm connector is designed for hospitals, surgical clinics, and OT units in Pakistan.Â
Specifications:
- Material: Medical grade siliconeÂ
- Connector Type: Standard plug that fits 6mm/6.3mm
- Compatibility: Fits most standard electrosurgical generators
- Reusability: Sterilizable with autoclave, can be resterilized multiple timesÂ
- Surface: Conductive, even current distribution
- Design: Flexible and conforms to skin for adults and childrenÂ
- Cable: Lightweight, low strain connector assembly
- Maintenance: Cleaning up is fast and between procedures.Â
- Application: Electrosurgery, diathermy, and cautery procedures
- Use Setting: Healthcare, dental & veterinary OTs
Reusable Silicone Patient Plate – Valleylab Connector
₨ 12,500
Autoclavable reusable silicone patient plate that can be directly used with Valleylab compatible electrosurgical generators. Designed to replace one time use adhesive pads with a long life, gel free system for high volume OT use.Â
Specifications:
- Type: Reusable silicone patient return plate (non adhesive)
- Connector: Valleylab style, direct plug in (adapter not required)Â
- Material: Medical grade conductive siliconeÂ
- Gel requirement: None
- Sterilization: Autoclavable / chemically sterilizableÂ
- Cable length: 3 metres (standard)Â
- Reusability: Multiple use, clean between procedures
- Compatibility: Valleylab and Valleylab compatible electrosurgical unitsÂ
- Waste impact: Minimizes the waste of disposable pads and biomedical waste

Reviews
There are no reviews yet.