Power Model HF-500 CT Electro Surgical Unit
The power model HF-500 CT electro surgical unit is a high frequency surgical generator designed for cutting and coagulation in operating theatres, minor OTs and speciality clinics. It is optimised for surgeons, OT technicians and hospital procurement teams that need reliable output in normal and complicated procedures.
Key Features & Benefits
- Dual mode operation (cut and coagulation): Switching between pure cutting, blend and coagulation modes without changing tools saves surgical time during multi step surgery with the power model HF-500 CT electro surgical unit.Â
- Monopolar and bipolar output: Helpful in general surgery and/or in delicate surgical procedures, such as gynaecological or ENT surgery, where bipolar control minimizes thermal spread to adjacent tissues.
- Adjustable power output: The power model HF-500 CT electro surgical unit Power can be adjusted to the particular procedure and type of tissue, allowing the same unit to be used for minor dermatological work and larger general surgeries.Â
- Digital display with real time settings: The power model HF-500 CT electro surgical unit allows OT staff to verify power levels instantly, minimizing setup mistakes during busy periods.Â
- Isolated output circuitry: Reduces the chance of stray current burning at the return electrode site, which is a significant safety feature of any electrosurgical unit.
- Audible and visual alarms: If the return electrode connection becomes faulty, or if the output goes out of a safe range, it will be noticed immediately by the staff.
- Compact, mobile trolley design: The power model HF-500 CT electro surgical unit easily fits into small OT rooms prevalent in Pakistani private hospitals and clinics and can be moved easily between rooms.Â
Who Should Buy This / Use Cases
This power model HF-500 CT electro surgical unit is suitable for hospitals, surgical clinics, and diagnostic centres throughout Pakistan that conduct general surgery, gynaecology, ENT, or minor surgical procedures. Where load shedding and voltage fluctuations are still prevalent, the combination of a stable power model HF-500 CT electro surgical unit with appropriate voltage stabilization or UPS backup helps to keep the equipment and patient safe during surgical procedures.Â
Dual mode will be beneficial for private clinics with existing basic cautery equipment looking to expand their treatment offerings. This is a middle of the road solution for the distribution of general surgical items at district hospitals and smaller nursing homes and is practical for stocking because it includes the items needed for general surgery but excludes a high end multi specialty system.Â
Why Choose Capasee Electro Medical Engineering
Capasee Electro Medical Engineering has been providing and servicing electro medical equipment designed for the local power supply and operating conditions to hospitals and clinics all over Pakistan. The power model HF-500 CT electro surgical unit includes installation guidance, staff orientation to safe usage, and after sales service for repairs and spare parts.
This is important in a market where equipment downtime may cause delays in patient care. Buyers of the power model HF-500 CT electro surgical unit can have their technical questions directly addressed instead of through an existing manual.Â
Frequently Asked Questions
What is the electro surgical unit used for?
High frequency electrical current is used to cut tissue and stop bleeding (coagulation) during surgery with an electrosurgical unit. It is used throughout various specialties such as general surgery, gynecology, ENT, dermatology, etc.
What is the cost of electrosurgical unit?
They range in price based on the size of the power output, the type of modes (monopolar/bipolar), and the brand, from low cost models for small procedures to higher cost models for multi specialty procedures. Please consult Capasee Electro Medical Engineering for up to date pricing on the HF-500 CT.
What is another name for electrosurgery?
Electrosurgery is also known as diathermy or radiofrequency surgery, depending on the region and the method employed.
What is the frequency of current used in electrosurgery unit?
The standard frequency range for electrosurgical units is radiofrequency, usually between 300 kHz and 5 MHz, where cutting and coagulation can be performed without stimulation of nerves and muscles as would occur with lower frequency current.
What is the voltage of electrofulguration?
The higher the voltage, the lower the current, which is typical for electrofulguration, as it is meant for destroying surface tissue, not for a clean cut, as would occur in cutting. The precise voltage required will depend upon the unit and the power setting chosen by the surgeon.
Get in Touch
To see a live demonstration of the power model HF-500 CT electro surgical unit or for the latest prices and specifications, please contact Capasee Electro Medical Engineering to discuss with their medical engineering team.